help button home button Endocrine Society JCEM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Submit a related Letter to the Editor
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Copyright Permission
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Smith, T. P.
Right arrow Articles by McKenna, T. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Smith, T. P.
Right arrow Articles by McKenna, T. J.
The Journal of Clinical Endocrinology & Metabolism Vol. 87, No. 12 5410-5415
Copyright © 2002 by The Endocrine Society


Special Feature

Gross Variability in the Detection of Prolactin in Sera Containing Big Big Prolactin (Macroprolactin) by Commercial Immunoassays

Thomas P. Smith, Abdulwahab M. Suliman, Michael N. Fahie-Wilson and T. Joseph McKenna

Department of Endocrinology and Diabetes Mellitus (T.P.S., A.M.S., T.J.M.), St. Vincent’s University Hospital, Elm Park and the Conway Institute of Biomolecular and Biomedical Research (T.J.M.), University College, Dublin 4, Ireland; and Department of Clinical Chemistry (M.N.F.-W.), Southend Hospital, Westcliff-on-Sea, Essex SS0 0RY, United Kingdom

Address all correspondence and requests for reprints to: Prof. T. Joseph McKenna, Department of Endocrinology and Diabetes Mellitus, St. Vincent’s University Hospital, Elm Park, Dublin 4, Ireland. E-mail: tmckenna{at}svherc.ucd.ie.

Abstract

A high molecular mass form of prolactin (PRL), macroprolactin, accumulates in the sera of some subjects. Although macroprolactin exhibits limited bioactivity in vivo, it retains immunoreactivity. We examined the frequency of macroprolactinemia in clinical practice and the ability of immunoassay systems to distinguish between macroprolactin and monomeric PRL. Of 300 hyperprolactinemic sera identified, 71 normalized following treatment of sera with polyethylene glycol, indicating that 24% of hyperprolactinemia could be accounted for by macroprolactin. Ten of these macroprolactinemic sera were circulated to 18 clinical laboratories. Two sets of PRL measurements of the 10 untreated sera were obtained from each of the nine most commonly used immunoassay systems. Across the nine assay systems, differences in the PRL estimates ranged from 2.3- to 7.8-fold. Elecsys users reported the highest PRL levels. Somewhat lower values were reported for DELFIA systems followed by Immuno-1, AxSYM, and Architect assays. The Immulite 2000 assay generated PRL levels equivalent to approximately 50% of those reported by the high-reading methods. The lowest PRL levels were reported by Access, ACS:180, and Centaur systems. To avoid confusion caused by the frequent presence of macroprolactin accounting for hyperprolactinemia, secondary screening for the presence of macroprolactin is recommended.

FRACTIONATION OF HUMAN sera by gel filtration chromatography reveals that the polypeptide hormone prolactin (PRL) circulates in three discrete forms (1, 2). These include a monomer of molecular mass 23 kDa, which accounts for approximately 85% of the PRL present in normal individuals, a 50-kDa species accounting for 10–15%, and a small but variable amount of a high-molecular-mass form (~150 kDa) termed big big PRL or macroprolactin. In the case of sera from hyperprolactinemic individuals, the relative proportions of such circulating forms can be quite different (3, 4). The prevalence of macroprolactin in hyperprolactinemic sera has been reported as 15–26% (5, 6, 7, 8, 9). The possibility that confusion might arise from the coincidental finding of macroprolactinemia in the investigation of patients presenting with symptoms consistent with but not exclusive to hyperprolactinemia has received little attention.

The existence of macroprolactin was first reported over 25 yr ago (1). Although PRL polymers may account for a minor portion, macroprolactin is primarily a molecular complex of PRL and an IgG antibody thought to be directed against the PRL molecule (10, 11, 12, 13). Macroprolactin is cleared more slowly than monomeric PRL and hence accumulates in the sera of affected subjects. However, because of its high molecular mass, the autoimmune complex is confined to the vasculature and hence exhibits limited bioactivity in vivo (3, 14, 15, 16). As a consequence, subjects whose hyperprolactinemia can be accounted for by the presence of macroprolactin, i.e. have macroprolactinemia, may not exhibit the classic signs or symptoms of the hyperprolactinemic syndrome such as galactorrhea, menstrual irregularities, or infertility (3, 4, 17). However, these nonspecific symptoms prompt measurement of PRL. Although not causally related, some subjects may coincidentally demonstrate galactorrhea, menstrual irregularities, or infertility together with hyperprolactinemia entirely caused by macroprolactin. It is therefore important to distinguish such individuals from those with true hyperprolactinemia to avoid unnecessary biochemical and imaging investigations and misleading diagnosis and thus prevent inappropriate drug and surgical treatment (6, 9, 18, 19, 20, 21). It is equally important to correctly identify and address the underlying disorder responsible for the clinical presentation in these patients.

Screening for hyperprolactinemia assumes that the assays used to measure PRL will provide clinically relevant results. Moreover, the widespread use of a common international calibration standard should ensure that PRL estimations are consistent, irrespective of the methodology used. However, current PRL immunoassays in routine use exhibit variable degrees of reactivity with macroprolactin. In a limited study, the United Kingdom National External Quality Assessment Scheme (UK NEQAS) reported that PRL estimations on serum from one macroprolactinemic individual varied from 476 mU/liter to 3212 mU/liter and that the variability was dependent on the immunoassay used (22). In a somewhat more comprehensive investigation, Cavaco et al. (16) reported results obtained when several macroprolactinemic sera were examined with four commercially available immunoassays. The PRL levels varied widely from assay to assay. Moreover, the relative sensitivity of the assays to macroprolactin was variable for the sera examined, i.e. the ranking of PRL values was not consistent among assays. The variable behavior of different macroprolactinemic sera in any given assay and the extent of reactivity of macroprolactin in several widely used immunoassay systems may lead to misdiagnosis in clinical practice (6, 9, 18, 19, 20, 21). To address this problem, polyethylene glycol (PEG) immunoprecipitation has been advocated as one means whereby macroprolactin can be removed from sera before measurement of PRL (5, 6, 7, 23). Although results generated using PEG correlate well with those of gel filtration, numerically they differ significantly, a finding that can be explained by the nonspecific way PEG reduces protein solubility (24). Moreover, PEG interferes with a considerable number of commonly used immunoassay methodologies and as such its use is not always applicable.

In the present study, we examined the frequency with which macroprolactin accounted for hyperprolactinemia in our practice. To examine the extent to which macroprolactinemia is related to the assay system, we submitted 10 hyperprolactinemic serum samples known to contain predominantly macroprolactin to nine of the most commonly used immunoassay systems. The content of monomeric PRL in the sera was determined following gel filtration chromatography. In addition, these serum samples were assayed for PRL following treatment with PEG. We also wished to determine whether the relative sensitivity of the PRL immunoassays for different macroprolactinemic samples was the same or variable and recognizing that the absolute values achieved were likely to differ. This examination was undertaken to provide insight as to whether the autoantibody giving rise to macroprolactin was directed against one or several discrete epitopes on the PRL molecule.

Subjects and Methods

Subjects

We identified 300 sera with PRL levels in excess of 700 mU/liter using the PRL DELFIA immunoassay routinely used in our laboratory. These were derived from a general endocrinology service in a university-affiliated teaching hospital and tertiary referral center. In addition, the levels of PRL in the pre- and post-PEG-treated sera from 62 healthy normoprolactinemic control subjects were established. For a diagnosis of macroprolactinemia to be made in this study, it was necessary for PEG treatment to correct hyperprolactinemia to levels obtained in normoprolactinemic sera following PEG treatment.

A study was undertaken to evaluate the clinical management of hyperprolactinemic patients when it was not known that macroprolactin was the cause (21). Ten patients identified as having macroprolactin as the major circulating form of PRL in their sera agreed to participate in the immunoassay cross-reactivity portion of the study. No other selection criteria were applied. There were eight women, mean age 42 ± 12 yr, and two men, mean age 42 ± 2 yr. Whole blood, approximately 600 ml, was collected by venepuncture and allowed to clot. Serum recovered by centrifugation was aliquoted and stored at -20 C before dispatch to participating laboratories for analysis. The clinical characteristics and PRL levels before and after treatment with PEG of the 10 patients studied are outlined in Table 1Go. Of the eight female patients studied, three presented with both oligomenorrhea and galactorrhea. Three additional patients were identified during routine investigations for breast disease. The two male patients in the study complained either of infertility or loss of libido. Serum total PRL levels measured by the DELFIA analyzer system (Wallac, Inc., Turku, Finland) in the 10 patients ranged from 750-3975 mU/liter. Following treatment with PEG and removal of the macroprolactin complex, PRL levels fell to less than 380 mU/liter in each case with recoveries of PRL ranging from 6–33%.


View this table:
[in this window]
[in a new window]
 
Table 1. Clinical characteristics and serum PRL levels in the patients under investigation

 
Methods

The study was conducted in association with the Irish External Quality Assessment Scheme and involved 13 clinical laboratories in the Republic of Ireland that routinely measure PRL. In addition, five laboratories in the United Kingdom were invited to participate. The analytical methods used by the participants were all automated and included two of each of the following instruments: Architect and AxSYM (Abbott, Abbott Park, IL); Immuno-1, ACS 180, and Centaur (Bayer Corp., Pittsburgh, PA); Access (Beckman, Brea, CA); Immulite 2000 (Diagnostic Products, Los Angeles, CA); Elecsys (Roche, Indianapolis, IN); and DELFIA (Wallac, Inc.). All the above immunoassays are calibrated to the World Health Organization international reference preparation for PRL 84/500.

The amount of macroprolactin present in the sera under investigation was quantified by DELFIA following gel filtration over Sephacryl S-300 (50 x 1.5 cm; 30 ml/h; Pharmacia, Uppsala, Sweden) equilibrated in 10 mmol/liter Tris, 140 mmol/liter NaCl, 1.25 mmol/liter CaCl2, and 0.5 mmol/liter Mg Cl2 (pH 7.4), as described previously (5). In addition, all specimens were subjected to treatment with an equal volume of 25% (wt/vol) PEG in PBS (pH 7.4) for 10 min at room temperature before centrifugation (1800 x g, 30 min) and reanalysis of the supernatant using the DELFIA system. Recovery of monomeric PRL (DELFIA recombinant standard) following PEG treatment was 97 ± 2%. To examine the reproducibility of PEG precipitation applied to sera containing significant but different absolute amounts of macroprolactin, we repeated the examination on a number of occasions. The interassay coefficients of variation for this procedure were 5.3% for serum with a mean total PRL of 297 mU/liter and a mean level of 128 mU/liter following PEG treatment (n = 43), 5.6% for sera with a mean total PRL of 627 mU/liter and a mean level of 291 mU/liter following PEG treatment (n = 34), and 4.9% for serum with mean total PRL of 1229 mU/liter and a mean level of 139 mU/liter following PEG treatment (n = 22).

Statistical analysis

Pearson correlation coefficients and t tests were determined using the statistical package Analyze It [Microsoft Corp. Excel (25)]. A P value less than 0.05 was accepted as statistically significant. Data were expressed as means and SD.

The study was approved by the Research Ethics Committee, St. Vincent’s University Hospital, and all participants provided informed consent.

Results

Prevalence of macroprolactinemia to account for hyperprolactinemia

Three hundred randomly selected hyperprolactinemic serum samples, i.e. PRL levels in excess of 700 mU/liter as determined by the DELFIA (Wallac, Inc.), were submitted to PEG treatment. As a control group, sera from 62 normal healthy women were examined and found to have total PRL levels ranging from 78–466 mU/liter. PEG treatment of the 62 normoprolactinemic control sera yielded PRL levels of 197 ± 146 mU/liter (mean ± 2 SD). The absolute levels ranged from 70–390 mU/liter, and this was used as a reference or normal range for serum treated in this way.

Seventy-one of the 300 hyperprolactinemic samples yielded PRL levels of less than 390 mU/liter following treatment with PEG. Therefore, 24% of hyperprolactinemic sera could be accounted for by the presence of macroprolactin. The percentage of sera with PRL levels in excess of 1000 mU/liter whose PRL levels corrected following treatment with PEG was 19%, and the percentage of patients with PRL levels in excess of 2000 mU/liter, which corrected to less than 390 mU/liter, was 8%. In our patients, therefore, the higher the PRL level, the less frequently macroprolactin accounts for hyperprolactinemia.

Serum PRL estimations using nine different immunoassay systems

Two operators of nine different assay systems each received 10 hyperprolactinemic sera samples known to contain a variable amount of macroprolactin that when processed to remove macroprolactin and remeasured yielded PRL levels within the normal range. Thus, these sera samples were deemed to have mild to severe hyperprolactinemia, which was corrected when macroprolactin was removed. Table 2GoGo illustrates the mean PRL levels in the 10 serum specimens examined as reported by nine different immunoanalyzer systems. We have arranged the PRL levels in the sera samples with increasing PRL levels tabulated from left to right against the assay systems, generally giving the highest to lowest values running from top to bottom. In addition, the monomeric PRL content of each sample isolated by gel filtration chromatography is also provided for reference purposes. These data are presented graphically in Fig. 1Go. Serum PRL levels reported by the commercially available systems for any given specimen varied from 2.3- to 7.8-fold between the highest and lowest estimations, depending on the serum examined. In all cases Elecsys (Roche) users reported the highest serum PRL levels (mean range, 828-4604 mU/liter). Somewhat lower values were reported by DELFIA (Wallac, Inc.) users (range, 743-4133 mU/liter) followed in general by users of the Immuno-1 (Bayer Corp.) (range, 640-3690 mU/liter), AxSYM (Abbott) (448–3021 mU/liter) and Architect (Abbott) (range, 452-2982 mU/liter). Users of Immulite 2000 (DPC) reported PRL levels ranging from 393-1837 mU/liter, approximately 50% of the values as measured by the high reading methods, Elecsys (Roche), DELFIA (Wallac, Inc.), Immuno-1 (Bayer Corp.), and AxSYM and Architect (Abbott). The lowest PRL levels were reported by ACS:180 (Bayer Corp.) (range, 290-1189 mU/liter), Centaur (Bayer Corp.) (range, 243–947 mU/liter), and Access (Beckman) (range, 228–940 mU/liter) users.


View this table:
[in this window]
[in a new window]
 
Table 2A. Mean serum PRL levels (mU/liter) in 10 sera assayed by 9 analytical methods

 

View this table:
[in this window]
[in a new window]
 
Table 2B. PRL levels (mU/liter) reported by the individual laboratories participating in the study for each of the 10 macroprolactinemic sera

 


View larger version (22K):
[in this window]
[in a new window]
 
Figure 1. Mean serum PRL levels reported by nine different immunoanalyzer user groups in specimens collected from 10 macroprolactinemic subjects. For comparative purposes, the PRL level in each specimen following removal of macroprolactin by gel filtration is shown.

 
Nearly consistent stratification of PRL measurements across different assay systems was observed in the 10 sera. In other words, when the individual sera PRL values were ranked from lowest to highest, the hierarchy obtained tended to be reproducible for each of the nine methods examined with only minor deviations (Table 2GoGo). The Access (Beckman) and Centaur (Bayer Corp.) systems each gave a reading in excess of 700 mU/liter for only 1 of the 10 macroprolactinemic samples assayed. The ACS:180 system (Bayer Corp.) yielded values in excess of 700 mU/liter in 2 of the 10 macroprolactinemic samples. Using the Immulite 2000 (DPC), 4 of the 10 samples crossed the 700 mU/liter threshold, 7 of 10 samples using the Architect (Abbott), 8 of 10 samples using the AxSYM (Abbott) and the Immuno-1 (Bayer Corp.), and all 10 samples had measured PRL in excess of 700 mU/liter using the DELFIA (Wallac, Inc.) and Elecsys (Roche). In 9 of the 10 samples examined, PRL levels measured by DELFIA (Wallac, Inc.) following the removal of macroprolactin by gel filtration were considerably lower than those reported by any of the immunoanalyzer systems using sera that had not been fractionated (Table 2GoGo and Fig. 1Go).

Measurement of serum PRL following gel filtration chromatography or pretreatment with PEG

Gel filtration chromatography provides the reference method for isolation of monomeric PRL. The mean PRL value obtained following PEG precipitation in the 10 macroprolactinemic sera distributed, 201 ± 90 mU/liter, were consistently lower than those obtained following chromatographic separation and quantitation of monomeric PRL, 303 ± 133 mU/liter (P < 0.001, Table 2GoGo). When the PRL values obtained following treatment of serum with PEG were correlated against those obtained following chromatographic isolation of monomeric PRL, the correlation coefficient obtained was 0.92 (P < 0.001).

Discussion

Measurement of PRL is one of the most commonly undertaken hormonal investigations in evaluating patients with reproductive disorders. Hyperprolactinemia accounts for menstrual disorders in approximately one fifth of affected women (26). Recently reports have suggested that hyperprolactinemia may be accounted for by the presence of macroprolactin in 15–26% of cases (5, 6, 7, 8, 9). In general, macroprolactin is regarded as biologically inactive. The diagnosis of hyperprolactinemia when it is entirely due to the presence of macroprolactin gives rise to mismanagement of patients whose symptoms may arise from another disorder and in whom macroprolactinemia is coincidental. A small number of reports have suggested that the extent to which the presence of macroprolactin is recognized in sera is assay system dependent (16, 22, 27, 28). It is important therefore that those performing assays and reporting results and those responsible for their interpretation and the management of patients are aware of the extent to which the assay system used in the measurement of PRL may detect macroprolactin. When it is recognized that the assay system used is highly sensitive to the presence of macroprolactin, it is prudent that an alternative procedure is introduced to ensure that macroprolactin levels are reported. The present study was undertaken to examine the extent to which widely used PRL assays systems failed to distinguish between macroprolactin and monomeric PRL.

Although there was no assay system that succeeded in providing normoprolactinemic values in all the sera known to contain macroprolactin, the performance of the Centaur (Bayer Corp.) and the Access (Beckman) and to a lesser degree the ACS:180 (Bayer Corp.) was superior to that of the other assay systems examined. It is therefore particularly important that those using the Immulite 2000 (DPC), AxSYM (Abbott), Architect (Abbott), Immuno-1 (Bayer Corp.), DELFIA (Wallac, Inc.), and Elecsys (Roche) should undertake specific steps to identify the presence of macroprolactin when hyperprolactinemia is detected. Treatment of hyperprolactinemic sera with PEG and remeasurement of PRL is one strategy that could be adopted. However, this will mean a more labor-intensive and costly procedure requiring two PRL measurements. In addition, PEG interference with a number of immunoassay formats [AxSYM (Abbott), ACS:180 (Bayer Corp.), Immuno-1 (Bayer Corp.)] has limited its general applicability. Furthermore, the procedure is prone to underrecovery of monomeric PRL in sera, compared with the reference procedure gel filtration (5, 7).

Assessment of the number of users using the various assay systems examined to generate PRL results revealed that in total they accounted for 91% of UK NEQAS and 85% of College of American Pathologist proficiency testing program participants (29, 30). Twelve percent of United Kingdom laboratories and 5% of United States laboratories used either of the two assay systems that gave PRL values in excess of 700 mU/liter in 10 of 10 macroprolactinemic samples. Forty-six percent of United Kingdom laboratories and 44% of United States laboratories use assay systems that identified PRL levels of greater than 700 mU/liter in 7 or more of the 10 macroprolactinemic samples. Eighteen percent of United Kingdom participants and 30% of United States PRL quality assurance scheme participants use either the Access (Beckman) or the Centaur (Bayer Corp.) that identified a serum PRL value in excess of 700 mU/liter in only 1 of the 10 macroprolactinemic samples. Although it is recognized that the number of participants using a particular system may not reflect the relative number of samples analyzed in the assay systems because of variability of numbers processed in different centers, the information derived from analysis of the United Kingdom and United States PRL assay quality assurance programs is useful. A conservative estimate suggests that 5–10% of the total hyperprolactinemic samples reported in the United Kingdom and United States may be accounted for by the presence of macroprolactin. When a macroprolactinemic sample was circulated to UK NEQAS participants and feedback sought for the likely explanation for the finding of hyperprolactinemia, only 22% of responders suggested the possibility of macroprolactin (22). It is likely that the phenomenon of macroprolactinemia is considerably underestimated and underrecognized.

The diagnosis of macroprolactinemia previously was based on the observation that more than 60% of PRL was in the macroprolactin form as indicated by gel filtration chromatography or less than 40% of the PRL measured in untreated serum was recovered following treatment of the serum with PEG (5, 6, 7). This convention does not acknowledge that although macroprolactin could account for more than 60% of total PRL, the level of biologically active monomeric PRL could still be present in significant excess. Thus patients have been reported to have macroprolactinemia who also had monomeric PRL levels well in excess of normal values, e.g. greater than 1200 mU/liter (6). It appears prudent that more demanding criteria for the diagnosis of macroprolactinemia be introduced. When PEG treatment of hyperprolactinemic sera is used, the diagnosis of macroprolactinemia might be confined to those whose serum PRL level falls to that seen in sera from normoprolactinemic subjects treated with PEG, i.e. less than 390 mU/liter using the Delfia (Wallac, Inc.) immunoassay. This would avoid any confusion as to whether biologically active PRL is also in excess when excess macroprolactin is present.

The variability of immunoassays to detect macroprolactin has been noted previously (5, 12, 16). This probably relates to the extent to which the epitope on the PRL molecule that attracts the endogenous autoantibody reacts with the site toward which the antibodies used in the assay system are directed. Thus, if the site required for recognition in an assay is occupied by the endogenous antibody, the assay will not recognize PRL even when present in large amounts as occurs in patients with macroprolactinemia. The absolute PRL levels measured in any serum demonstrated a wide range, depending on the assay system used. In contrast, the ranking of the 10 samples within the various assay systems from highest to lowest level is nearly constant. It is therefore likely that the endogenous antibody present in the 10 sera examined is directed against a single epitope on PRL. However, not all sera behave in this predictable manner, suggesting that autoantibodies directed against different epitopes also exist (16, 27, 28).

Macroprolactinemia is a largely unrecognized phenomena and has not been discussed in recent comprehensive endocrinology texts (31, 32), although it has been recently reported to account for up to 26% of hyperprolactinemic samples (9). The present study has confirmed that the extent to which macroprolactin contributes to the total PRL reported is assayed system dependent. Assay systems examined, encompassing 91% of United Kingdom and 85% of United States routine methods for measuring PRL, identified hyperprolactinemia in at least 1 of the 10 samples in which hyperprolactinemia could be accounted for entirely by the presence of macroprolactin. The extent to which macroprolactin was identified varied greatly among assay systems examined. Those responsible for providing PRL results and those responsible for the interpretation and management of patients reported to have hyperprolactinemia should be aware of the extent to which macroprolactin may contribute to hyperprolactinemia in assay systems used locally.

Acknowledgments

We are grateful to those clinical laboratories that participated in the study and the Irish External Quality Assessment Scheme (www.IEQAS.ie) organizers for their cooperation.

Footnotes

Abbreviations: PEG, Polyethylene glycol; UK NEQAS, United Kingdom National External Quality Assessment Scheme.

Received December 6, 2001.

Accepted September 2, 2002.

References

  1. Suh HK, Frantz AG 1974 Size heterogeneity of human prolactin in plasma and pituitary extracts. J Clin Endocrinol Metab 39:928–935[Abstract/Free Full Text]
  2. Smith CR, Norman MR 1990 Prolactin and growth hormone: molecular heterogeneity and measurement in serum. Ann Clin Biochem 27:542–550
  3. Jackson RD, Wortsman J, Malarkey WB 1985 Characterisation of a large molecular weight prolactin in women with idiopathic hyperprolactinemia and normal menses. J Clin Endocrinol Metab 61:258–264[Abstract/Free Full Text]
  4. Larrea F, Escorza A, Valero A, Hernandrz L, Cravioto MC, Diaz-Sanchez V 1989 Heterogeneity of serum prolactin throughout the menstrual cycle and pregnancy in hyperprolactinemic women with normal ovarian function. J Clin Endocrinol Metab 68: 982–987
  5. Fahie-Wilson MN, Soule SG 1997 Macroprolactinemia: contribution to hyperprolactinemia in a district general hospital and evaluation of a screening test based upon precipitation with polyethylene glycol. Ann Clin Biochem 34:252–258
  6. Olukoga AO, Kane JW 1999 Macroprolactinemia: validation and application of the polyethylene glycol precipitation test and clinical characterisation of the condition. Clin Endocrinol 51:119–126[CrossRef][Medline]
  7. Gilberto J, Vieira H, Tachibana TT, Obara LH, Maciel RMB 1998 Extensive experience and validation of polyethylene glycol precipitation as a screening method for macroprolactinemia. Clin Chem 44:1758–1789[Free Full Text]
  8. Bjoro I, Morkrid K, Wereland R, Turter A, Kvistborg A, Sand T, Torjesen P 1995 Frequency of hyperprolactinemia due to large molecular weight prolactin (150–170 kDa PRL). Scand J Clin Invest 55:139–147[Medline]
  9. Leslie H, Courtney CH, Bell PM, Hadden DR, McCance DR, Ellis PK, Sheridan B, Atkinson AB 2001 Laboratory and clinical experience in 55 patients with macroprolactinemia identified by a simple polyethylene glycol precipitation method. J Clin Endocrinol Metab 86: 2743–2746
  10. Cavaco B, Leite V, Santos AM, Arranhado E, Sobrinho LG 1995 Some forms of big-big prolactin behave as a complex of monomeric prolactin with an immunoglobulin G in patients with macroprolactinemia or prolactinoma. J Clin Endocrinol Metab 80:2342–2346[Abstract]
  11. Hattori N, Ishihara T, Ikekubo K, Moridera K, Hino M, Kurahachi H 1992 Auto-antibody to human prolactin in patients with idiopathic hyperprolactinemia. J Clin Endocrinol Metab 75:1226–1269[Abstract]
  12. Leite V, Cosby H, Sobrinho LG, Fresnoza A, Santos MA, Friesen HG 1992 Characterisation of big, big prolactin in patients with hyperprolactinemia. Clin Endocrinol 37:365–372[Medline]
  13. Hattori N, The frequency of macroprolactin in pregnant women and the heterogeneity of its aetiologies. J Clin Endocrinol Metab 81:586–590
  14. Hattori N, Inagaki C 1997 Anti-prolactin (PRL) autoantibodies cause asymptomatic hyperprolactinemia: bioassay and clearance studies of PRL-immunoglobulin G complex. J Clin Endocrinol Metab 82:3107–110[Abstract/Free Full Text]
  15. Hattori N, Ikekubo K, Ishihara T, Moridera K, Hino M, Kurahachi H 1994 Correlation of the antibody titres with serum prolactin levels and their clinical course in patients with anti-prolactin autoantibody. Eur J Endocrinol 130:438–445[Abstract/Free Full Text]
  16. Cavaco B, Prazeres S, Santos MA, Sobrinho LG, Leite V 1999 Hyperprolactinemia due to big-big prolactin is differently detected by commercially available immunoassays. J Endocrinol Invest 22:203–208[Medline]
  17. Hattori N, Ikekubo K, Ishihara T, Moridera K, Hino M, Kurahachi H 1992 A normal ovulatory woman with hyperprolactinemia: presence of anti-prolactin autoantibody and the regulation of prolactin secretion. Acta Endocrinol (Copenh) 126:497–500
  18. Heaney AP, Laing I, Walton L, Seif MW, Beardwell CG, Davis JRE 1999 Misleading hyperprolactinemia in pregnancy. Lancet 353:720[CrossRef][Medline]
  19. Olukoga AO, Dorman TL, Kane JW 1999 Three cases of macroprolactinemia. J R Soc Med 92:342–344[Abstract]
  20. Guay AT, Sabharwal P, Varma S, Malarky WB 1996 Delayed diagnosis of psychological erectile dysfunction because of the presence macroprolactin. J Clin Endocrinol Metab 81:2512–2514[Abstract]
  21. Suliman AM, Sharma J, Smith TP, McKenna TJ Macroprolactin: an easily identified cause of inappropriate investigation and treatment. Program of the 82nd Annual Meeting of The Endocrine Society, Toronto, Canada, 2000; p. 552 (Abstract 2288)
  22. Seth J, Sturgeon CM, Ellis AR, Al-Sadie R, Logan M 1998 UK NEQAS for peptide hormones and related substances. Annu Rev A1–A4 (Appendix)
  23. Hattori N, Ikekubo K, Ishiahra T, Moridera K, Hino M, Kurahachi H 1994 Effects of anti-prolactin autoantibodies on serum prolactin measurements. Eur J Endocrinol 130:434–447[Abstract/Free Full Text]
  24. Wild D 2001 Separation systems. In: Wild D, ed. The immunoassay handbook, ed 2. London: Nature Publishing Group; 150
  25. Altman DG 1997 Practical statistics for medical research, ed 1. London: Chapman, Hall; 213–215
  26. Sarapura V, Shlaff WD 1993 Recent advances in the understanding of the pathophysiology and treatment of hyperprolactinemia. Curr Opin Obstet Gynaecol 5:360–367[Medline]
  27. Schneider W, Marcovitz S, Al-Shammari S, Yago S, Chevalier S 2001 Reactivity of macroprolactin in common automated immunoassays. Clin Biochem 34:469–473[CrossRef][Medline]
  28. Gilson G, Schmit P, Thix J, Hoffman JP, Humbel L 2001 Prolactin results for samples containing macroprolactin are method and sample dependent. Clin Chem 47:331–333[Free Full Text]
  29. Seth J, Sturgeon CM, Ellis AR, Al-Sadie R, Logan M 2000 UK NEQAS for peptide hormones and related substances. Annual Review, p. 14
  30. Elin RJ 2001 College of American Pathologists Special Ligands Participants Summary Report; p. 7
  31. Thorner MO, Vance ML, Edward R, Laws Jr ER, Horvathe E, Kovacs K 1998 The anterior pituitary. In: Wilson JD, Foster DW, Kronenberg HM, Larsen PR, eds. Williams textbook of endocrinology, ed 9. Philadelphia: WB Saunders; 249–340
  32. Delitala G 1998 Hyperprolactinemia: causes, biochemical diagnosis and tests for prolactin secretion. In: Grossman A, eds. Clinical endocrinology, ed 2. Oxford: Blackwell Science Ltd; 138–147
  33. Molitch ME, Russell EJ 1990 The pituitary "incidentaloma." Ann Intern Med 112:925–931



This article has been cited by other articles:


Home page
Clin. Chem.Home page
L. Beltran, M. N. Fahie-Wilson, T. J. McKenna, L. Kavanagh, and T. P. Smith
Serum Total Prolactin and Monomeric Prolactin Reference Intervals Determined by Precipitation with Polyethylene Glycol: Evaluation and Validation on Common ImmunoAssay Platforms
Clin. Chem., October 1, 2008; 54(10): 1673 - 1681.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
L. Kavanagh, T. J. McKenna, M. N. Fahie-Wilson, J. Gibney, and T. P. Smith
Specificity and Clinical Utility of Methods for the Detection of Macroprolactin
Clin. Chem., July 1, 2006; 52(7): 1366 - 1372.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Endocrinol. Metab.Home page
A. Glezer, C. R. J. Soares, J. G. Vieira, D. Giannella-Neto, M. T. C. P. Ribela, V. Goffin, and M. D. Bronstein
Human Macroprolactin Displays Low Biological Activity via Its Homologous Receptor in a New Sensitive Bioassay
J. Clin. Endocrinol. Metab., March 1, 2006; 91(3): 1048 - 1055.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
J. Schiettecatte, A. Van Opdenbosch, E. Anckaert, J. De Schepper, K. Poppe, B. Velkeniers, and J. Smitz
Immunoprecipitation for Rapid Detection of Macroprolactin in the Form of Prolactin-Immunoglobulin Complexes
Clin. Chem., September 1, 2005; 51(9): 1746 - 1748.
[Full Text] [PDF]


Home page
J. Clin. Endocrinol. Metab.Home page
J. Gibney, T. P. Smith, and T. J. McKenna
The Impact on Clinical Practice of Routine Screening for Macroprolactin
J. Clin. Endocrinol. Metab., July 1, 2005; 90(7): 3927 - 3932.
[Abstract] [Full Text] [PDF]


Home page
Rheumatology (Oxford)Home page
S. Ram, D. Blumberg, P. Newton, N. R. Anderson, and R. Gama
Raised serum prolactin in rheumatoid arthritis: genuine or laboratory artefact?
Rheumatology, October 1, 2004; 43(10): 1272 - 1274.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
T. C. Friedman, W. T. Couldwell, M. H. Weiss, E. R. Laws Jr., G. L. Hortin, A. Colao, G. Lombardi, and J. Schlechte
Prolactinomas
N. Engl. J. Med., March 4, 2004; 350(10): 1054 - 1057.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
A. M. Suliman, T. P. Smith, J. Gibney, and T. J. McKenna
Frequent Misdiagnosis and Mismanagement of Hyperprolactinemic Patients before the Introduction of Macroprolactin Screening: Application of a New Strict Laboratory Definition of Macroprolactinemia
Clin. Chem., September 1, 2003; 49(9): 1504 - 1509.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Endocrinol. Metab.Home page
J. A. Schlechte
The Macroprolactin Problem
J. Clin. Endocrinol. Metab., December 1, 2002; 87(12): 5408 - 5409.
[Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Submit a related Letter to the Editor
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Copyright Permission
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Smith, T. P.
Right arrow Articles by McKenna, T. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Smith, T. P.
Right arrow Articles by McKenna, T. J.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Endocrinology Endocrine Reviews J. Clin. End. & Metab.
Molecular Endocrinology Recent Prog. Horm. Res. All Endocrine Journals