| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
From the Clinical Research Centers |
Liver Research Unit, Royal Infirmary of Edinburgh, University of Edinburgh (S.H.S., S.S.M., H.S., P.C.H.), EH3 9YW Edinburgh, Scotland; Department of Medicine, General Clinical Research Center, and National Science Foundation Center for Biological Timing, University of Virginia Health Sciences Center (J.D.V.), Charlottesville, Virginia 22908; and Division of Endocrinology, Keck School of Medicine (S.H.S., P.C.B.), Los Angeles, California 90033
Address all correspondence and requests for reprints to: Dr. Peter C. Butler, Division of Endocrinology and Diabetes, Keck School of Medicine, University of Southern California, 1333 San Pablo Street, BMT-B11, Los Angeles, California 90033. E-mail: pbutler{at}hsc.usc.edu
| Abstract |
|---|
|
|
|---|
| Introduction |
|---|
|
|
|---|
In the current study we applied a validated deconvolution technique for quantifying pulsatile insulin secretion to plasma insulin concentration profiles obtained simultaneously from the portal vein and the systemic circulation in human subjects with stable compensated hepatic cirrhosis and an in situ transjugular intrahepatic portasystemic stent shunt (TIPSS) (16). The TIPSS catheter allowed relatively noninvasive high frequency sampling of blood from the portal vein in conscious human subjects. Pulsatile insulin secretion was quantified in the fasting basal state as well as during a hyperglycemic clamp study.
Using this protocol we sought to address the following
questions. First, is the frequency of pulsatile insulin secretion in
humans (observed by direct sampling from the portal circulation)
comparable to the frequency reported previously from studies in
isolated islets, the isolated pancreas, and in vivo by
sampling from the portal vein in dogs (interpulse interval,
68 min
or
1520 min as reported in some studies using the systemic
sampling site in humans). Second, does hyperglycemia in the human (as
in the dog) enhance insulin secretion through the specific mechanism of
augmenting the mass of insulin bursts? Finally, we examined whether the
amplitude of the insulin concentration wavefront to which the liver is
exposed in humans approaches that observed in the portal vein of dogs
(5, 6).
| Subjects and Methods |
|---|
|
|
|---|
This study was approved by the Lothian ethics committee (institutional review board equivalent), and all volunteers provided informed written consent. Inclusion criteria were patients with a patent TIPSS and known stable compensated liver disease. Patients were deliberately selected to represent those in which the predominant liver-related problem was cirrhosis and portal vein hypertension treated with a TIPSS, rather than progressive liver failure or active hepatic inflammation. Exclusion criteria include decompensated liver dysfunction, diabetes mellitus, a thrombosed stent, and/or a prolonged prothrombin time. All patients were studied 12 weeks before the TIPSS study and had a 75-g oral glucose tolerance test performed to exclude diabetes mellitus. Of six subjects screened, one was excluded from the study because of diabetes.
|
Study protocol
All study subjects were admitted to the University of Edinburgh Wellcome Trust Clinical Research Facility at the Royal Infirmary of Edinburgh the night before the study and remained fasting overnight. On the morning of the study, each subject underwent TIPSS portogram performed by a radiologist as part of the routine follow-up assessment of the patency of the in situ TIPSS, and the sampling catheter was placed in the portal vein at the end of this procedure.
A peripheral indwelling sampling catheter was also inserted into a dorsal hand vein and the hand was warmed to 40 C by an electric blanket to permit subsequent sampling of arterialized blood. An iv catheter was also placed in an antecubital vein in the contralateral arm and infused with saline at 30 mL/h. Once all of the catheters were in place there was a 45-min rest period before commencement of the protocol at approximately 1000 h. At protocol time 040 min, simultaneous intensive 1-min sampling of arterialized blood and portal vein blood was performed to obtain the minutely insulin concentration profile at each site in the fasting state. At protocol time 40 min, a hyperglycemic clamp was commenced with the object of raising the arterialized plasma glucose concentration to 89 mmol/L. This was achieved by infusion of a variable rate glucose infusion (50% dextrose) administered by a programmable infusion pump (Harvard Infusion Pumps, Ayer, MA) on-line to a personal computer. Arterialized blood was sampled at 5-min intervals, and plasma glucose was measured within 2 min. Steady state hyperglycemia was achieved by protocol time 80 min (40 min after the clamp was begun), and then the second sampling period began. From protocol time 80120 min, blood was sampled at 1-min intervals from the arterialized peripheral vein catheter and the portal vein catheter to determine the insulin concentration profile during the hyperglycemic clamp. Portal vein sampling was completed in all five study subjects in both the basal and hyperglycemic sampling periods. Arterialized sampling was completed in four of the five subjects; the peripheral sampling catheter was unreliable in the remaining subject. In two subjects portal vein blood flow was measured during the study by use of Doppler scanning.
Assays
Plasma glucose concentrations were measured by the glucose oxidase method using a glucose analyzer (Beckman Coulter, Inc., Palo Alto, CA).
Plasma insulin concentrations were measured in duplicate by two-site immunospecific insulin enzyme-linked immunosorbent assay (ELISA), as previously described (11, 17). In brief, the assay uses two monoclonal murine antibodies (Novo Nordisk, Bagsvaerd, Denmark) specific for human insulin. The detection range of this insulin ELISA was 5600 pmol/L. At medium (150 pmol/L), medium-high (200 pmol/L), and high (350 pmol/L) plasma insulin concentrations, the interassay coefficients of variation were 3.7%, 4.0%, and 4.5%, and the corresponding intraassay variations were 2.3%, 2.1%, and 2.0%. There was no cross-reactivity with proinsulin or split 32,33 and des-31,32 proinsulins, respectively.
The plasma C peptide concentration was assayed with a commercially available kit (K6218, DAKO Corp., Cambridgeshire, UK). The assay is a two-site ELISA based on two monoclonal antibodies, using the principles referred to above. Each sample was assayed in duplicate; intra- and interassay coefficients of variation were 2.2% and 3.3%, respectively.
Data analysis: detection and quantification of pulsatile insulin secretion by deconvolution analysis
The plasma insulin concentration-time series were analyzed by deconvolution as previously validated (18) to detect and quantify insulin secretory bursts (6). Deconvolution of plasma insulin concentration data was performed with a multiparameter technique that requires the following assumptions. Plasma insulin concentrations measured in samples collected at 1-min intervals were assumed to result from five determinable and correlated parameters: 1) a finite number of discrete insulin secretory bursts occurring at either regular or randomly dispersed times and having a) individual amplitudes (maximal rate of secretion attained within a burst) and mass (integral of the calculated secretory event) and b) a common half-duration (duration of an algebraically Gaussian secretory pulse at half-maximal amplitude), which are superimposed on c) a basal time-invariant insulin secretory rate; 2) a biexponential insulin disappearance model in the systemic circulation, consisting of earlier directly estimated half-lives of 2.8 and 5.0 min and a fractional slow component of 0.28 in healthy fasting humans; and 3) a biexponential insulin disappearance model in the portal circulation, consisting of half-lives of 1.0 and 3.0 min and a fraction slow component of 0.667. These parameters achieved the statistically best fit (maximally reduced fitted variance) of the portal vein insulin concentration profile. All secretory rates were expressed as mass units of insulin (picomoles) released per unit distribution volume (liters) per unit time (minutes). As the volume of distribution of insulin is unknown in the portal sampling site in humans and undoubtedly differs from that in the systemic circulation, insulin secretion rates obtained at these two sampling sites cannot be directly compared.
Statistical analysis
Data are presented as the mean ± SEM. Statistical comparison between groups was made using Students two-tailed t test. To examine the relationship between insulin concentration fluctuations observed in the portal vein and systemic circulation, cross-correlation was performed (19). Cross-correlation analysis relates each portal vein insulin concentration to a corresponding value in the matching arterial series. This procedure consists of linear correlations carried out repeatedly at various time lags between the paired concentrations. Thus, at zero time lag, each portal vein plasma insulin concentration is compared with a time delayed measure (e.g. lag time minus 2 min) in the systemic circulation sample. By this means, an array of correlations can be collected that depend on the time matching of the two series.
To examine the relationship between pulses identified in the portal vein and systemic circulation we also performed peak concordance on these pulses from both sites. Peak concordance is a statistically independent (from cross-correlation) method to establish the relationship between detected pulses in two sampling sites. After identifying discrete insulin secretory bursts in the two time series (portal and peripheral), exact coincidence was defined by simultaneous pulse concordance (i.e. peak maxima occurred within one half-sampling interval of each other). Lagged coincidence was defined accordingly [e.g. with portal (+lags) or peripheral (-lags] peaks occurring first. The hypergeometric probability density (joint binomial distribution) was used to estimate the expected number of randomly concordant pulses, and the probability of falsely refuting the null hypothesis of pure chance concordance of the observed coincidences.
| Results |
|---|
|
|
|---|
The mean arterialized plasma glucose concentrations during the
basal (fasting) and stimulated (hyperglycemic clamp) sampling periods
were 5.3 ± 0.3 and 8.1 ± 0.1 mmol/L, respectively
(P < 0.001). As expected, there was a rise in the mean
arterialized (basal vs. stimulated, 209 ± 7.4
vs. 456 ± 16.8 pmol/L, p < 0.001) and mean portal
vein (basal vs. stimulated, 440 ± 25.3 vs.
1020.7 ± 72.3 pmol/L; P < 0.001) insulin
concentration after the increase in the plasma glucose concentration
from 5.3 to 8 mmol/L during the hyperglycemic clamp. The mean
arterialized C peptide concentration also increased with hyperglycemia
(basal vs. stimulated, 1.8 ± 0.1 vs.
2.7 ± 0.1 nmol/L; P < 0.001), confirming an
increase in insulin secretion in response to the glucose stimulus.
Throughout the study in each subject, the portal vein insulin
concentration was higher than the corresponding arterialized insulin
concentration in both basal (P < 0.001) and stimulated
(P < 0.001) sampling periods (Fig. 1
).
|
The mean portal vein blood flow values in the two cases in which it was measured were 1.1 and 0.8 L/min. There was no change in the portal vein blood flow between the basal state and the hyperglycemic clamp.
Insulin concentration profiles (Figs. 2
and 3
)
Inspection of the plasma insulin concentration profiles from the
individual patients indicated the presence of recurrent oscillations in
both arterial and portal circulations in all patients. The magnitude of
these oscillations was much larger in the portal circulation (Fig. 2
)
in both the basal and stimulated states compared with the corresponding
profiles from the systemic circulation. The amplitude of the
oscillations increased during hyperglycemia (Fig. 2
). The range of the
insulin pulse amplitude observed in the portal circulation was 100-1000
pmol/L in the basal state and increased to 200-3000 pmol/L during the
hyperglycemic clamp. This contrasts with the corresponding range of
pulse amplitudes observed in the systemic circulation of 1030 and
40100 pmol/L in the basal and stimulated states, respectively
(Fig. 3
).
|
|
When the insulin concentration profiles were subjected to
deconvolution, insulin pulses were invariably identified in both the
portal and systemic circulation (Figs. 4
and 5
). The pulse mass increased in
response to hyperglycemia in both portal (basal vs.
stimulated, 418 ± 155 vs. 1078 ± 368 pmol/L;
P < 0.05) and systemic (basal vs.
stimulated, 75 ± 10 vs. 241 ± 61 pmol/L;
P < 0.05) circulations (Fig. 6
). Furthermore, the measured pulse
mass/volume of distribution was about 5-fold larger in the portal
circulation in both basal and stimulated states. The pulse amplitude
determined by deconvolution was also markedly (7- to 8-fold) larger in
the portal circulation in both basal (portal vs. systemic,
254 ± 158 vs. 23 ± 2.7 pmol/L·min) and
stimulated (portal vs. systemic, 524 ± 337
vs. 72 ± 19.8 pmol/L·min) states, confirming the
impression gained by inspection of the insulin concentration profiles.
The corresponding four pulse half-duration estimates were similar, with
a global mean of 2.9 min. The interpulse interval (Fig. 6
) determined
by direct portal vein sampling was similar in the basal sampling period
and during the clamp (Fig. 6
). The pulse interval detected by sampling
from the systemic circulation was slightly, but not significantly,
higher than that observed in the portal circulation.
|
|
|
|
|
| Discussion |
|---|
|
|
|---|
Our conclusion that most insulin secreted into the portal circulation is derived from pulses is contingent upon the assumptions required for the deconvolution method employed (see Materials and Methods). It should also be noted that the half-life for insulin used in these studies for portal vein insulin concentration deconvolution was obtained by a best-fit approach to the portal vein insulin concentration profiles. Direct measurement of the volume of distribution or half-life at this site by a bolus injection upstream of the TIPSS sampling catheter in a mesenteric vein is not practicable in conscious humans. Nonetheless, similar studies in dogs with surgically implanted catheters arrived at the same conclusion that most insulin is secreted in discrete insulin bursts (6). Also, a prior study in humans sampling from the systemic circulation came to the same conclusion (11).
There has been some disagreement in the literature about the frequency of pulsatile insulin secretion in vivo, with estimates ranging from about 6 (5, 6) to about 20 (2, 3, 4, 7, 8) min. When we measured pulsatile insulin release directly from the canine portal vein, the interpulse interval averaged 6 min, based on a conventional insulin immunoassay and a deconvolution program specifically validated for insulin pulse detection (5, 6). Although this pulse frequency corresponded to that observed in perfusion of single islets in vitro, it was 3 times greater than that observed previously in humans by sampling from the systemic circulation (2, 3, 4, 7, 8). We postulated that the reason for this large discrepancy was the relative loss of insulin signal when insulin pulses are examined in the systemic compared with the portal circulation (6).
At least in the canine model, we confirmed that the sampling site was crucial when a conventional insulin assay was employed (5), as simultaneous estimates in the portal vein and the systemic circulation revealed insulin interpulse intervals of 6.7 and 9 min, respectively (5). The insulin pulse detection was further obscured by using a 2-min sampling regimen in the systemic circulation, as employed in some previous reports (7). The disadvantages of sampling from the systemic circulation were especially evident when the only available insulin assays were conventional immunoassays (20). Even multiple replicates by these assays, which have cross-reactivity with proinsulin and insulin split products, do not allow for fully reliable detection of high frequency insulin pulses in the systemic circulation. However, the introduction of the more sensitive and specific ELISA assays for insulin (17) should theoretically overcome some of these problems. Recently, using an ELISA for insulin measurements, we reported an insulin pulse frequency of approximately 8 min when sampling in the systemic circulation in humans (11, 12). The present study now confirms directly that the systemic sampling route can provide an accurate estimate of insulin pulse frequency in vivo in humans when the insulin concentration is measured by a sensitive and specific ELISA method and submitted to appropriate deconvolution-based analysis.
Sampling directly from the portal circulation revealed a remarkable magnitude of insulin oscillations at this site. In the present study the amplitude of insulin concentrations in the portal vein was about 200-1000 pmol/L in the basal state and increased to about 500-5000 pmol/L during hyperglycemia. These values in the human are comparable with those observed in the canine portal vein (5, 6) and presumably reflect the insulin concentration wavefront to which the liver is exposed. Although the present study subjects were necessarily only those with portal hypertension requiring treatment, we selected subjects with normal or near-normal liver function tests who were clinically well and had normal prestudy OGTTs. Moreover, the range of insulin oscillations observed in the portal vein in these subjects is comparable to that previously observed in healthy dogs (5, 6), and the portal vein blood flow, when available, was in the normal reported range for humans. Although some studies have reported that pulsatile insulin delivery (to the peripheral circulation) enhances insulin sensitivity, none has yet recapitulated the magnitude of insulin oscillations to which the liver is exposed in vivo during stimulated enhanced insulin secretion (21, 22). The question remains, therefore, what the physiological importance is, if any, of exposing the liver to such dramatic oscillations of insulin concentration. As the magnitude of peripheral insulin pulses is decreased in patients with type 2 diabetes (23), it is likely that the liver in these patients is exposed to even more attenuated oscillations in insulin pulse amplitude, which may contribute to the hepatic insulin resistance characteristic of this disease (24).
The remarkable transhepatic attenuation of the insulin pulse signal
from the portal circulation to the systemic circulation observed here
is comparable to that observed previously in the dog (5).
Although the attenuation may reflect up to an approximately 4-fold
dilution of portal venous blood by the systemic venous drainage, the
insulin pulse amplitude is damped to a much greater extent than this
(
10-fold). One potential explanation for this is preferential
hepatic insulin clearance of insulin pulses. We previously noted that
the hepatic clearance of portal vein insulin in the dog is related in
an ascending monotonic (quadratic) manner to the pulse amplitude of the
insulin concentration wavefront presented to the liver
(25). Taken together, these preliminary observations
provoke the need for additional studies to address this possibility of
a link between pulse waveform and hepatic insulin clearance. In one
prior study in which blood was sampled from the portal vein of patients
with cirrhosis, comparable large oscillations in insulin concentration
were observed, although no quantification of pulsatile insulin release
or corresponding arterial sampling was available (26).
In summary, direct sampling from the portal vein in humans establishes an insulin interpulse interval of about 5 min and thereby resolves the discrepant insulin pulse frequency previously reported in humans. A comparable insulin interpulse interval can also be detected by high frequency peripheral sampling with the use of a highly sensitive insulin assay and appropriately validated pulse detection. Direct portal vein sampling is consistent with prior studies in dogs and humans, which reported that the majority of insulin is secreted in insulin bursts. Finally, we confirm that the liver in humans, like that in dogs, is exposed to dramatic insulin concentration oscillations that far exceed the magnitude evaluated to date in clinical studies of insulin action in vivo.
|
| Acknowledgments |
|---|
| Footnotes |
|---|
Received January 27, 2000.
Revised May 11, 2000.
Revised July 7, 2000.
Accepted September 1, 2000.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
B. Hellman, A. Salehi, E. Gylfe, H. Dansk, and E. Grapengiesser Glucose Generates Coincident Insulin and Somatostatin Pulses and Antisynchronous Glucagon Pulses from Human Pancreatic Islets Endocrinology, December 1, 2009; 150(12): 5334 - 5340. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. V. Matveyenko, J. D. Veldhuis, and P. C. Butler Adaptations in pulsatile insulin secretion, hepatic insulin clearance, and {beta}-cell mass to age-related insulin resistance in rats Am J Physiol Endocrinol Metab, October 1, 2008; 295(4): E832 - E841. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. V. Matveyenko, J. D. Veldhuis, and P. C. Butler Measurement of pulsatile insulin secretion in the rat: direct sampling from the hepatic portal vein Am J Physiol Endocrinol Metab, September 1, 2008; 295(3): E569 - E574. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. L. Beith, E. U. Alejandro, and J. D. Johnson Insulin Stimulates Primary {beta}-Cell Proliferation via Raf-1 Kinase Endocrinology, May 1, 2008; 149(5): 2251 - 2260. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Gauna, P. Uitterlinden, P. Kramer, R. M. Kiewiet, J. A. M. J. L. Janssen, P. J. D. Delhanty, M. O. van Aken, E. Ghigo, L. J. Hofland, A. P. N. Themmen, et al. Intravenous Glucose Administration in Fasting Rats Has Differential Effects on Acylated and Unacylated Ghrelin in the Portal and Systemic Circulation: A Comparison between Portal and Peripheral Concentrations in Anesthetized Rats Endocrinology, November 1, 2007; 148(11): 5278 - 5287. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. A. Ritzel, J. J. Meier, C.-Y. Lin, J. D. Veldhuis, and P. C. Butler Human Islet Amyloid Polypeptide Oligomers Disrupt Cell Coupling, Induce Apoptosis, and Impair Insulin Secretion in Isolated Human Islets Diabetes, January 1, 2007; 56(1): 65 - 71. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. D. Johnson, E. Bernal-Mizrachi, E. U. Alejandro, Z. Han, T. B. Kalynyak, H. Li, J. L. Beith, J. Gross, G. L. Warnock, R. R. Townsend, et al. Insulin protects islets from apoptosis via Pdx1 and specific changes in the human islet proteome PNAS, December 19, 2006; 103(51): 19575 - 19580. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. J. Meier, I. Hong-McAtee, R. Galasso, J. D. Veldhuis, A. Moran, B. J. Hering, and P. C. Butler Intrahepatic transplanted islets in humans secrete insulin in a coordinate pulsatile manner directly into the liver. Diabetes, August 1, 2006; 55(8): 2324 - 2332. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. V. Matveyenko and P. C. Butler {beta}-Cell Deficit Due to Increased Apoptosis in the Human Islet Amyloid Polypeptide Transgenic (HIP) Rat Recapitulates the Metabolic Defects Present in Type 2 Diabetes. Diabetes, July 1, 2006; 55(7): 2106 - 2114. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. S. Luciani, S. Misler, and K. S. Polonsky Ca2+ controls slow NAD(P)H oscillations in glucose-stimulated mouse pancreatic islets J. Physiol., April 15, 2006; 572(2): 379 - 392. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. J. Meier, L. L. Kjems, J. D. Veldhuis, P. Lefebvre, and P. C. Butler Postprandial suppression of glucagon secretion depends on intact pulsatile insulin secretion: further evidence for the intraislet insulin hypothesis. Diabetes, April 1, 2006; 55(4): 1051 - 1056. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. A. Ritzel, J. D. Veldhuis, and P. C. Butler The mass, but not the frequency, of insulin secretory bursts in isolated human islets is entrained by oscillatory glucose exposure Am J Physiol Endocrinol Metab, April 1, 2006; 290(4): E750 - E756. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. J. Michael, R. A. Ritzel, L. Haataja, and R. H. Chow Pancreatic {beta}-Cells Secrete Insulin in Fast- and Slow-Release Forms Diabetes, March 1, 2006; 55(3): 600 - 607. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. J. Meier, J. D. Veldhuis, and P. C. Butler Pulsatile Insulin Secretion Dictates Systemic Insulin Delivery by Regulating Hepatic Insulin Extraction In Humans Diabetes, June 1, 2005; 54(6): 1649 - 1656. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. A. Hedman, J. Frystyk, T. Lindstrom, J.-W. Chen, A. Flyvbjerg, H. Orskov, and H. J Arnqvist Residual {beta}-Cell Function More than Glycemic Control Determines Abnormalities of the Insulin-Like Growth Factor System in Type 1 Diabetes J. Clin. Endocrinol. Metab., December 1, 2004; 89(12): 6305 - 6309. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. A. Ritzel, J. B. Hansen, J. D. Veldhuis, and P. C. Butler Induction of {beta}-Cell Rest by a Kir6.2/SUR1-Selective KATP-Channel Opener Preserves {beta}-Cell Insulin Stores and Insulin Secretion in Human Islets Cultured at High (11 mM) Glucose J. Clin. Endocrinol. Metab., February 1, 2004; 89(2): 795 - 805. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. H. Song, C. J. Rhodes, J. D. Veldhuis, and P. C. Butler Diazoxide Attenuates Glucose-Induced Defects in First-Phase Insulin Release and Pulsatile Insulin Secretion in Human Islets Endocrinology, August 1, 2003; 144(8): 3399 - 3405. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. E. Gunton, P. J. D. Delhanty, S.-I. Takahashi, and R. C. Baxter Metformin Rapidly Increases Insulin Receptor Activation in Human Liver and Signals Preferentially through Insulin-Receptor Substrate-2 J. Clin. Endocrinol. Metab., March 1, 2003; 88(3): 1323 - 1332. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. A. Ritzel, J. D. Veldhuis, and P. C. Butler Glucose Stimulates Pulsatile Insulin Secretion from Human Pancreatic Islets by Increasing Secretory Burst Mass: Dose-Response Relationships J. Clin. Endocrinol. Metab., February 1, 2003; 88(2): 742 - 747. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Porksen, T. Grofte, J. Greisen, A. Mengel, C. Juhl, J. D. Veldhuis, O. Schmitz, M. Rossle, and H. Vilstrup Human insulin release processes measured by intraportal sampling Am J Physiol Endocrinol Metab, March 1, 2002; 282(3): E695 - E702. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Gilon, M. A. Ravier, J.-C. Jonas, and J.-C. Henquin Control Mechanisms of the Oscillations of Insulin Secretion In Vitro and In Vivo Diabetes, February 1, 2002; 51(90001): S144 - 151. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. H. Song, L. Kjems, R. Ritzel, S. M. McIntyre, M. L. Johnson, J. D. Veldhuis, and P. C. Butler Pulsatile Insulin Secretion by Human Pancreatic Islets J. Clin. Endocrinol. Metab., January 1, 2002; 87(1): 213 - 221. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. L. Kjems, B. M. Kirby, E. M. Welsh, J. D. Veldhuis, M. Straume, S. S. McIntyre, D. Yang, P. Lefebvre, and P. C. Butler Decrease in {beta}-Cell Mass Leads to Impaired Pulsatile Insulin Secretion, Reduced Postprandial Hepatic Insulin Clearance, and Relative Hyperglucagonemia in the Minipig Diabetes, September 1, 2001; 50(9): 2001 - 2012. [Abstract] [Full Text] [PDF] |
||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Endocrinology | Endocrine Reviews | J. Clin. End. & Metab. |
| Molecular Endocrinology | Recent Prog. Horm. Res. | All Endocrine Journals |