help button home button Endocrine Society JCEM JCEM Call for Nominations for EIC
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

Journal of Clinical Endocrinology & Metabolism, doi:10.1210/jc.2007-2340
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
93/5/1804    most recent
Author Manuscript (PDF)
Right arrow Submit a related Letter to the Editor
Right arrow Purchase Article
Right arrow View Shopping Cart
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Copyright Permission
Google Scholar
Right arrow Articles by Binkley, N.
Right arrow Articles by Drezner, M. K.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Binkley, N.
Right arrow Articles by Drezner, M. K.
Related Collections
Right arrow Calcium and Bone Metabolism
The Journal of Clinical Endocrinology & Metabolism Vol. 93, No. 5 1804-1808
Copyright © 2008 by The Endocrine Society

Correlation among 25-Hydroxy-Vitamin D Assays

N. Binkley, D. Krueger, D. Gemar and M. K. Drezner

University of Wisconsin Osteoporosis Clinical Center & Research Program, University of Wisconsin, Madison, Wisconsin 53705

Address all correspondence and requests for reprints to: Neil Binkley, M.D., 2870 University Avenue, Suite 100, Madison, Wisconsin 53705. E-mail: nbinkley{at}wisc.edu.

Context: Measurement of circulating 25-hydroxy-vitamin D [25(OH)D]) is the accepted clinical indicator of vitamin D status. However, between-laboratory differences in measurement of this analyte exist, which may confound clinical care.

Objectives: We investigated the current agreement of 25(OH)D measurement in clinical laboratories and explored the possibility that simple calibration would improve between-laboratory agreement.

Design and Participants: Serum obtained from healthy volunteers (age 20–60 yr) and one "calibrator," selected to have a 25(OH)D value near 30 ng/ml, were sent for 25(OH)D measurement in four clinical laboratories (laboratories A–D) using HPLC, liquid chromatography tandem mass spectroscopy, and RIA methodologies.

Main Outcome Measures: Serum 25(OH)D. Based upon self-report, the laboratory with the lowest interassay percent coefficient of variation was assigned as the reference to which the others were compared using linear regression and Bland-Altman analyses (Analyse-it; Analyse-it Software, Ltd., Leeds, UK).

Results: Good correlation was observed for 25(OH)D measurement between laboratory A and laboratories B–D (R2 = 0.99, 0.81, and 0.95, respectively). Modest between-laboratory variation was noted; the mean bias ranged from 2.9–5.2 ng/ml. Consistent with a systematic offset, each value in laboratory B was higher than in laboratory A, and 89% of values from laboratories B–D were higher than laboratory A. The use of a single calibrator and correction factor reduced mean between-laboratory bias for laboratories B and D.

Conclusions: Measurement of 25(OH)D by clinical laboratories yields similar results. The use of even a single calibrator will improve, but not resolve, between-laboratory variability. Based upon these data, in combination with reported within-individual variability, we recommend that clinicians aim for values greater than 30 ng/ml in their patients.