help button home button Endocrine Society JCEM JCEM Call for Nominations for EIC
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a related Letter to the Editor
Right arrow Purchase Article
Right arrow View Shopping Cart
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Copyright Permission
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Preissner, C. M.
Right arrow Articles by Grebe, S. K. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Preissner, C. M.
Right arrow Articles by Grebe, S. K. G.
The Journal of Clinical Endocrinology & Metabolism Vol. 88, No. 7 3069-3074
Copyright © 2003 by The Endocrine Society

Phantoms in the Assay Tube: Heterophile Antibody Interferences in Serum Thyroglobulin Assays

Carol M. Preissner, Dennis J. O’Kane, Ravinder J. Singh, John C. Morris and Stefan K. G. Grebe

Departments of Laboratory Medicine and Pathology (C.M.P., D.J.O’K., R.J.S., S.K.G.G.) and Medicine (J.C.M., S.K.G.G.), Mayo Clinic, Rochester, Minnesota 55905

Address all correspondence and requests for reprints to: Dr. Stefan K. G. Grebe, Department of Laboratory Medicine and Pathology, Mayo Clinic, 200 1st Street SW, Rochester, Minnesota 55905. E-mail: grebs{at}mayo.edu.

Serum thyroglobulin (Tg) measurement is a major means of detecting thyroid cancer recurrence. Unlike anti-Tg autoantibody interferences, heterophile antibody (HAB) immunoassay interferences are not well recognized by laboratorians or clinicians as a Tg assay problem. When HAB interferences occur, they usually result in false positive test results. With the current trend to treat some thyroid cancer patients with radioiodine on the basis of an elevated serum Tg result alone, this has the potential to result in unwarranted therapy.

We evaluated the prevalence of HAB interference in a commonly used automated immunoassay in 1106 consecutive specimens with Tg values greater than 1 ng/ml. All Tg measurements were repeated after sample incubation in heterophile-blocking tubes (HBT). Results, which showed a more than 3 SD percentage difference from the original result, were considered to suffer from HAB interference. All possible interferences were confirmed by dilution testing.

After HBT treatment, Tg levels dropped to less than 1 ng/ml in 32 specimens (P < 0.0000001), 20 of which fell to less than 0.1 ng/ml (P < 0.00002). Of these 20, 17 were anti-Tg autoantibody negative, and all 32 showed a fall of greater than 3 SD percentage (>56.91%) compared with the original result. There were also two samples that showed a significant increase of greater than 56.91% after HBT treatment.

HAB interference is relatively prevalent (1.5–3%) in a commonly used automated Tg assay and can lead to clinically significant artifacts. It is currently unknown, but possible, that other immunometric Tg assays suffer from similar problems. Unless a Tg assay is confirmed to be free of HAB interference or uses additional blocking steps, as ours now does, HAB interference should be suspected if Tg results do not fit the clinical picture.

This work was supported by the Mayo Clinic Department of Laboratory Medicine and Pathology and the Mayo Foundation.

Abbreviations: CV, Coefficient(s) of variation; HAB, heterophile antibody; HAMA, human antimouse antibodies; HBT, heterophile-blocking tubes; Ig, immunoglobulin; Tg, thyroglobulin.




This article has been cited by other articles:


Home page
Clin. Chem.Home page
L. Giovanella and A. Ghelfo
Undetectable Serum Thyroglobulin Due to Negative Interference of Heterophile Antibodies in Relapsing Thyroid Carcinoma
Clin. Chem., October 1, 2007; 53(10): 1871 - 1872.
[Full Text] [PDF]


Home page
J. Clin. Endocrinol. Metab.Home page
M. Schlumberger, A. Hitzel, M. E. Toubert, C. Corone, F. Troalen, M. H. Schlageter, F. Claustrat, S. Koscielny, D. Taieb, M. Toubeau, et al.
Comparison of Seven Serum Thyroglobulin Assays in the Follow-Up of Papillary and Follicular Thyroid Cancer Patients
J. Clin. Endocrinol. Metab., July 1, 2007; 92(7): 2487 - 2495.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
A. C.M. Persoon, J. M.W. Van Den Ouweland, J. Wilde, I. P. Kema, B. H.R. Wolffenbuttel, and T. P. Links
Clinical utility of an automated immunochemiluminometric thyroglobulin assay in differentiated thyroid carcinoma.
Clin. Chem., April 1, 2006; 52(4): 686 - 691.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Endocrinol. Metab.Home page
J. R. Stockigt
Ambiguous Thyroglobulin Assay Results in the Follow-Up of Differentiated Thyroid Carcinoma
J. Clin. Endocrinol. Metab., October 1, 2005; 90(10): 5904 - 5905.
[Full Text] [PDF]


Home page
J. Clin. Endocrinol. Metab.Home page
C. A. Spencer, L. M. Bergoglio, M. Kazarosyan, S. Fatemi, and J. S. LoPresti
Clinical Impact of Thyroglobulin (Tg) and Tg Autoantibody Method Differences on the Management of Patients with Differentiated Thyroid Carcinomas
J. Clin. Endocrinol. Metab., October 1, 2005; 90(10): 5566 - 5575.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
E. L. Mazzaferri
Empirically Treating High Serum Thyroglobulin Levels
J. Nucl. Med., July 1, 2005; 46(7): 1079 - 1088.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
M. J. Ellis and J. H. Livesey
Techniques for Identifying Heterophile Antibody Interference Are Assay Specific: Study of Seven Analytes on Two Automated Immunoassay Analyzers
Clin. Chem., March 1, 2005; 51(3): 639 - 641.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
C. M. Preissner, L. A. Dodge, D. J. O'Kane, R. J. Singh, and S. K.G. Grebe
Prevalence of Heterophilic Antibody Interference in Eight Automated Tumor Marker Immunoassays
Clin. Chem., January 1, 2005; 51(1): 208 - 210.
[Full Text] [PDF]


Home page
J. Clin. Endocrinol. Metab.Home page
C. A. Spencer
Challenges of Serum Thyroglobulin (Tg) Measurement in the Presence of Tg Autoantibodies
J. Clin. Endocrinol. Metab., August 1, 2004; 89(8): 3702 - 3704.
[Full Text] [PDF]


Home page
J. Clin. Endocrinol. Metab.Home page
G. Ward and P. E. Hickman
Phantoms in the Assay Tube
J. Clin. Endocrinol. Metab., January 1, 2004; 89(1): 433 - 433.
[Full Text] [PDF]


Home page
J. Clin. Endocrinol. Metab.Home page
S. K. G. Grebe
Authors' Response: Phantoms in the Assay Tube
J. Clin. Endocrinol. Metab., January 1, 2004; 89(1): 433 - 433.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Endocrinology Endocrine Reviews J. Clin. End. & Metab.
Molecular Endocrinology Recent Prog. Horm. Res. All Endocrine Journals
Copyright © 2003 by The Endocrine Society