Abstract
There is a significant systematic difference between the normal range obtained from ethylenediamine tetraacetate plasma samples using the Genentech total insulin-like growth factor I (IGF-I) RIA and normal ranges for other total IGF-I RIAs. To determine whether the quality of the assay standard was the cause of this systematic difference, we analyzed commercially available preparations of recombinant human IGF-I (rhIGF-I) typical of those used as IGF-I immunoassay standards along with our own well characterized rhIGF-I assay standard. For the commercial standards, high performance liquid chromatography-derived purities were low, and some vendor-assigned protein concentrations were inconsistent with values from quantitative amino acid analysis. The Genentech rhIGF-I assay standard was highly pure and quantitatively correct. However, the poor quality of some commercial rhIGF-I preparations was not the primary reason for the systematic discrepancy between the Genentech total IGF-I RIA normal range and most other normal ranges.
Most assays for total IGF-I are calibrated against the WHO International Reference Reagent (IRR) for IGF-I Immunoassays (87/518). The Genentech total IGF-I RIA is not calibrated against WHO IRR 87/518. The protein content assigned to WHO IRR 87/518 was a consensus value from a multicenter collaborative study. Physico-chemical analyses showed that WHO IRR 87/518 is Met-1-IGF-I of low purity (44%), and that the assigned protein content is higher than the value determined by quantitative amino acid analysis. Thus, assays that are calibrated against WHO IRR 87/518 will report total IGF-I concentrations in excess of actual values. We believe that calibration against WHO IRR 87/518 is the cause of the systematic discrepancy between the Genentech IGF-I assay normal range and most other normal ranges, and that much of the plasma IGF-I concentration data in the literature are of questionable accuracy.
This article has been cited by other articles:
![]() |
B. P Hauffa, N. Lehmann, M. Bettendorf, O. Mehls, H.-G. Dorr, N. Stahnke, H. Steinkamp, E. Said, M. B Ranke, and participating members of the German KIGS Board/Med Central laboratory reassessment of IGF-I, IGF-binding protein-3, and GH serum concentrations measured at local treatment centers in growth-impaired children: implications for the agreement between outpatient screening and the results of somatotropic axis functional testing Eur. J. Endocrinol., November 1, 2007; 157(5): 597 - 603. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. E. Wieringa and P. J. Trainer Harmonizing Growth Hormone Measurements: Learning Lessons for the Future J. Clin. Endocrinol. Metab., August 1, 2007; 92(8): 2874 - 2875. [Full Text] [PDF] |
||||
![]() |
N. Mauras, V. Quarmby, and D. C. Bloedow Pharmacokinetics of insulin-like growth factor I in hypopituitarism: correlation with binding proteins Am J Physiol Endocrinol Metab, October 1, 1999; 277(4): E579 - E584. [Abstract] [Full Text] [PDF] |
||||