help button home button Endocrine Society JCEM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Submit a related Letter to the Editor
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Copyright Permission
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kiyokawa, H.
Right arrow Articles by Tarui, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kiyokawa, H.
Right arrow Articles by Tarui, S.

Journal of Clinical Endocrinology & Metabolism, Vol 69, 616-621, Copyright © 1989 by Endocrine Society


ARTICLES

Hyperinsulinemia due to impaired insulin clearance associated with fasting hypoglycemia and postprandial hyperglycemia: an analysis of a patient with antiinsulin receptor antibodies

H Kiyokawa, N Kono, T Hamaguchi, M Kawachi, K Tajima, I Mineo, Y Yamada, T Shimizu, M Kuwajima and S Tarui
Second Department of Internal Medicine, Osaka University Medical School, Japan.

Antiinsulin receptor antibodies were detected in the serum of a patient with insulin-resistant diabetes. Fasting hypoglycemia and postprandial hyperglycemia recurred every day. The plasma insulin level was 553 +/- 359 pmol/L [77 +/- 50 microU/mL (mean +/- SD)] in the fasting state and rose above 7500 pmol/L postprandially. The glycemic clamp at 2.8 mmol/L (50 mg/dL) without insulin infusion revealed that the half-life of plasma endogenous insulin was 173 min, indicating severely impaired plasma insulin clearance. During the clamp the glucose infusion rate was almost constant (0.9-1.2 mg/kg.min) despite an exponential decline in the plasma insulin level from 460 pmol/L (65 microU/mL) to 129 pmol/L (18 microU/mL). Intravenous insulin administration did not appreciably accelerate the basal constant decrease in the plasma glucose level during the postabsorptive period. These results indicate the coexistence of marked insulin resistance and constant ability to decrease plasma glucose level. In in vitro experiments, antireceptor immunoglobulin G from this patient increased the fructose 2,6- bisphosphate concentration in the presence of glucagon (less than 0.1 nmol/L) in primary cultured rat hepatocytes. The antireceptor immunoglobulin G stimulated autophosphorylation of rat liver insulin receptor. We conclude that antiinsulin receptor antibodies could impair plasma insulin clearance, resulting in persistent hyperinsulinemia, and that continuous receptor stimulation by the antibodies was responsible for the development of hypoglycemia.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Endocrinology Endocrine Reviews J. Clin. End. & Metab.
Molecular Endocrinology Recent Prog. Horm. Res. All Endocrine Journals
Copyright © 1989 by The Endocrine Society