help button home button Endocrine Society JCEM JCEM Call for Nominations for EIC
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Submit a related Letter to the Editor
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Copyright Permission
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kikutani, M.
Right arrow Articles by Miura, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kikutani, M.
Right arrow Articles by Miura, S.

Journal of Clinical Endocrinology & Metabolism, Vol 47, 980-984, Copyright © 1978 by Endocrine Society


ARTICLES

Enzyme immunoassay of human chorionic gonadotropin employing beta- galactosidase as label

M Kikutani, M Ishiguro, T Kitagawa, S Imamura and S Miura

An enzyme-linked immunoassay was applied to the determination of hCG, a glycoprotein hormone usually assayed by RIA. For this purpose, an enzyme hormone conjugate was prepared by reacting hCG with beta-D- galactosidase (beta-Gal.) of E. coli in the presence of N-(m- maleimidobenzoyloxy) succinimide (MBS) as coupling reagent. The conjugate, after purification by affinity and gel chromatographies, was shown to exhibit sufficient enzyme activity and immunoactivity. The immunoassay of hCG was performed by the double antibody method and, using this assay, 0.4-250 mIU/ml hCG were detectable. This was about 10 times as sensitive as the RIA. Difficulty was experienced when this method was utilized for the determination of hCG in plasma samples from patients. Since the presence of the plasma may have affected this assay method, the following improvements were made: 1) the same volume of hormone-free plasma was added to the standard solutions of hCG, and 2) the volume of plasma sample was 10 microliter. The performance and validity of this assay were comparable to the RIA using [125I]hCG as tracer. The dose-response curves of both assay have the same slope and there was no significant difference between the values (correlation coefficient, Y = 0.96X + 1.53).





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Endocrinology Endocrine Reviews J. Clin. End. & Metab.
Molecular Endocrinology Recent Prog. Horm. Res. All Endocrine Journals
Copyright © 1978 by The Endocrine Society